Anti-Slip Solutions for Chemical Plants

Anti-slip solutions for chemical plants – GRP grating, chemical-resistant floor plates, ladder rung covers and coatings – have to do more than provide grip. On walkways, platforms and stairs, oils, solvents, acids, alkalis and water come into contact with steel, concrete and gratings. Conventional coverings can be attacked by chemicals, and hazardous (Ex) areas bring additional requirements.

Matching protective equipment: safety shoes with a liquid-resistant sole – see our guide to non-slip safety shoes.

We help you make hazard points in chemical plants safe in a targeted way. GRP gratings, anti-slip sheets, coatings and ladder rung covers can be adapted to different areas. On this page you will find typical problem zones, suitable product groups and advice on selection.

Worker on a walkway between tanks and pipework – anti-slip solutions for chemical plants

Typical slip hazards in chemical plants

  • Walkways and platforms on reactors, tanks and pipework
  • Gratings that become slippery due to drips and corrosion
  • Stairs and fixed ladders to plant components
  • Filling and transfer areas with spilled media
  • Bunds and tank farms with standing liquid
  • Hazardous areas with special requirements for materials

In chemical plants, maintenance and inspection often take place away from the regular walkways. Staff climb onto platforms, operate valves or take samples, often wearing protective equipment that restricts their vision and freedom of movement. That makes reliable grip all the more important at every point that is walked on regularly. Include rarely used access points and maintenance routes in your survey as well.

Anti-slip solutions for chemical plants

The following solutions can be used individually or in combination. Information on chemical resistance and suitability for Ex areas applies to versions with the corresponding test evidence, available on request.

Anti-slip grating for chemical plants

Anti-slip gratings made from glass-reinforced plastic (GRP) are an alternative to steel where corrosion is a problem. GRP does not rust and does not need painting. The gratings are available in various slip resistance classes and colours.

Static-dissipative GRP grating

In areas where electrostatic charging must be avoided, a static-dissipative GRP grating may be required. We will clarify whether a version is suitable for your area based on your requirements. Versions with the corresponding test evidence are available on request.

Chemical-resistant anti-slip sheets made to measure

GRP anti-slip sheets can be screwed onto existing gratings, steel plates or steps. For areas with chemical contact, please tell us the media and concentrations and we will check which version is suitable. Cut-to-size pieces and custom-made solutions are possible.

Anti-slip surfaces for Ex areas

Special requirements for materials apply in potentially explosive atmospheres. We offer anti-slip coverings and gratings for Ex areas in versions with the corresponding test evidence on request. Please let us know the zone classification of your area.

Securing ladder rungs and stairs

Fixed ladders are common in chemical plants. Anti-slip ladder rung covers improve grip on round or smooth rungs. For stairs, GRP stair nosings are a good choice.

Coatings for floors and bunded areas

Anti-slip floor coatings are suitable for concrete surfaces and transfer areas. For surfaces with chemical contact, we check suitability based on the media used.

Selection: what matters

Slip resistance: Annex 2 of the German workplace rule ASR A1.5 assigns slip resistance classes from R9 to R13 and, where applicable, a displacement space to work areas. Testing is carried out to DIN EN 16165:2023; older data refer to DIN 51130. ASR A1.5 sets out the basic requirements for floors in workplaces. Use this information as guidance for your risk assessment.

Substrate and media: Whether grating, chequer plate or concrete, the substrate determines the fixing method. Just as important are the media the surface comes into contact with. Tell us the substances, concentrations and temperatures.

Cleaning: Clarify whether water, steam or cleaning chemicals are used. These must also be compatible with the material.

Fixing: Plates are usually screwed or bonded. Special fixings are used on gratings. Adhesives must be compatible with the medium and the temperature.

How your enquiry works

  1. You describe the area, the substrate, the media and, where relevant, the Ex zone – ideally with photos and dimensions.
  2. We propose suitable products and clarify which test evidence your application requires.
  3. You receive an individual quotation, including for cut-to-size and custom-made solutions.

Suitable products

A selection from our range. We will be happy to provide sizes, versions, prices and delivery times on request.

Hog Heaven Max anti-fatigue mat

Hog Heaven Max anti-fatigue mat

Item no. DD-MA-4424

Extra-thick industrial workplace mat with a nitrile rubber surface and closed-cell foam core. Designed for harsh environments with slag, oil, grease or chemicals.

  • Approx. 22 mm, nitrile rubber/foam core
  • Black or yellow border
  • ASTM C1028-96: static coefficient of friction dry 0.87 / wet 0.85

Enquire about this product

Infinity Bubble ESD workplace mat

Infinity Bubble ESD workplace mat

Item no. DD-ERG-IN-ESD

Static-dissipative version of the Infinity Bubble for electrostatic protected areas. Combines ergonomic relief with resistance to ground to IEC 61340-4-1 for electronics manufacturing and laboratories.

  • ESD version, tested to IEC 61340-4-1
  • Foamed PU, approx. 14.5 mm
  • Suitable for cleanrooms (EN ISO 14644-1)

Enquire about this product

Complete Bubble fire-retardant workplace mat

Complete Bubble fire-retardant workplace mat

Item no. DD-ERG-STF

Fire-retardant PU workplace mat with a bubble profile that self-extinguishes when exposed to a naked flame. Suitable for areas with fire protection requirements; Complete Smooth (SX) is the smooth version.

  • Self-extinguishing, Cfl-s1 (EN 13501-1)
  • Approx. 15 mm thick
  • Edges do not curl up

Enquire about this product

Nitril workplace mat in nitrile rubber

Nitril workplace mat in nitrile rubber

Item no. DD-ERG-EN

Black workplace mat made from non-porous nitrile rubber for oily environments. Does not ripple or swell on contact with oil and withstands temperatures up to 90 °C.

  • Nitrile rubber, oil-resistant
  • 11 mm thick
  • For use from -40 to +90 °C

Enquire about this product

Conductive nitrile ESD mat

Conductive nitrile ESD mat

Item no. DD-ERG-ENC

Conductive nitrile rubber mat for ESD areas exposed to oil. Combines conductivity to EN 61340-5-1 with a robust, oil-resistant rubber surface.

  • Conductive to EN 61340-5-1
  • Nitrile rubber, oil-resistant
  • Cleanroom class ISO 3–9

Enquire about this product

Nitro workplace mat for oily areas

Nitro workplace mat for oily areas

Item no. DD-ERG-ENT

15 mm thick nitrile rubber mat with a grippy profile for very oily or wet workstations. Resistant to many acids and, for short periods, to hot swarf up to 150 °C.

  • Grip profile for oily/wet environments
  • Nitrile rubber, 15 mm
  • For use from -40 to +90 °C

Enquire about this product

Fatigue-Step Nitril anti-fatigue tile

Fatigue-Step Nitril anti-fatigue tile

Item no. DD-CB-SS010007

Interlocking rubber tiles with nitrile content for wet, oily work areas. Drainage holes let liquids run off; according to the manufacturer, the tiles also withstand welding spatter and swarf.

  • Rubber with 30% nitrile, 18 mm
  • 22 mm drainage holes
  • Slip test to DIN 51130

Enquire about this product

Suitable safety footwear

For areas with chemicals, alkalis and oils: liquid-resistant PU/HRO soles (FO), waterproof S7S versions and a ladder grip zone for plant platforms.

Safety shoe DRY LOW (S3), item no. DD-BS-CA-B0894-CWS

Safety shoe DRY LOW (S3)

item no. DD-BS-CA-B0894-CWS

  • Protection class: S3 WR CI HRO SRC
  • Sole: Liquid-resistant PU/HRO rubber sole
  • Sizes: 39-50

Enquire about this product

Safety shoe STRONG (S3S), item no. DD-BS-CA-B0887-CWA

Safety shoe STRONG (S3S)

item no. DD-BS-CA-B0887-CWA

  • Protection class: S3S HRO CI HI LG SC FO SR
  • Sole: Liquid-resistant PU/HRO rubber sole
  • Sizes: 39-48

Enquire about this product

Safety shoe POWERFUL (S7S), item no. DD-BS-CA-B0897-CWS

Safety shoe POWERFUL (S7S)

item no. DD-BS-CA-B0897-CWS

  • Protection class: S7S LG SC FO SR
  • Sole: Liquid-resistant PU/TPU sole
  • Sizes: 36-50

Enquire about this product

Filter all 256 models in the catalogue →

FAQ: anti-slip protection in chemical plants

Are chemical-resistant anti-slip sheets available made to measure?

Yes, anti-slip sheets can be made to measure. Chemical resistance depends on the medium, concentration and temperature. Versions with the corresponding test evidence are available on request.

Why use GRP anti-slip grating in chemical plants?

GRP anti-slip grating is used in chemical plants because it does not corrode like steel and is lightweight, which makes installation and maintenance easier. The slip-resistant surface improves grip in wet and oily conditions.

Which anti-slip surface is suitable for Ex areas?

The right anti-slip surface for Ex areas depends on the zone classification and the requirements of your explosion protection concept. We offer versions with the corresponding test evidence on request.

When does a static-dissipative GRP grating make sense?

A static-dissipative GRP grating makes sense where electrostatic charging must be avoided, for example in areas with flammable substances. Whether this applies to your area follows from your explosion protection concept. We will advise you on the available versions.


Would you like to make walkways, platforms or stairs in your chemical plant safer? Tell us the area, substrate and media, and we will check which anti-slip solution suits your plant.